What happens today
A dip tape, a sight glass or a single-technology level switch per tank. Consumption is worked out from deliveries, and an overflow is discovered from the ground.
Level sensing and control
Miquimon measures liquid level with ultrasonic, hydrostatic, capacitive or optical sensing and reports over LoRaWAN, NB-IoT or BLE. It reads level, reports it, and where the site allows it, drives a transfer or batching step.
Most sites know a tank is low when someone walks out and looks, or when a process stops. Where level is instrumented, the reading usually stops at a local display, so consumption is reconstructed from delivery dockets and overflow is caught by a bund rather than by a measurement. The sensor choice also changes with the tank, which is why single-technology level products fit a minority of a site's vessels.
A dip tape, a sight glass or a single-technology level switch per tank. Consumption is worked out from deliveries, and an overflow is discovered from the ground.
One platform covers the vessels a site actually has, reports level on a schedule with a battery that lasts years, and raises an alarm on the condition the site defined rather than on a fixed float height.
A level sensor chosen per vessel, a battery node, and a record of level and consumption per tank.
Non-contact ultrasonic through the container wall, submersible hydrostatic pressure, external capacitive for plastic and glass, or optical point level for high and low alarms — selected per vessel rather than imposed on it.
A battery-powered node reporting over LoRaWAN, NB-IoT or BLE, with the five to ten year autonomy target that makes instrumenting a remote tank practical.
Level against time per vessel, which gives consumption rate, the next replenishment window and the evidence for an alarm that fired at three in the morning.
Miquimon ships as a level sensor and node per vessel with the mounting the vessel needs, plus the record store and alarm path; control outputs are quoted with the vessel they serve.
The record below is a sample tank history showing level, consumption and the alarm that fired. It is illustrative and is not a capture from a customer's site.
Sample record. Values are illustrative and are not customer data.
The moat is the sensing range across vessel types plus the consumption record. A site that can instrument every vessel with one platform gets a consumption trend per tank, which is what turns a level product into a loss-detection tool.
Miquimon reports level at the vessel where a sensor is fitted and cannot report on a vessel that has none. Ultrasonic sensing is affected by foam, heavy vapour and build-up on the transducer face, hydrostatic sensing reads the head above the sensor rather than the whole vessel, and capacitive sensing needs a non-metallic wall. A control output depends on a working link unless a local fallback is configured. The kit is built to order, and supply timing is confirmed in the written quotation.
Miquimon measures and reports what its sensors see. That is monitoring, not a compliance or safety certification: the log is evidence of what the equipment recorded, and nothing on this page, in the quotation or on the invoice certifies your site, your process or your equipment against any standard.
One product page S5 owns. The first 3 years of service are included in the up-front project price; from year 4 the subscription is A$10 per site / month. The hardware and the scope are quoted against a site assessment, and the quotation carries that figure. Nothing is sold directly from this page: the listed price is recorded through a written quotation, and the quotation states the lead time, the freight and the payment terms for your site.
| Piece | What happens | Status |
|---|---|---|
| Quotation | A written quotation is issued for this page and the configuration shown | Issued on request |
| Buy now | Opens the quotation page: the listed price is recorded against a written quotation, no order, no payment | A$10 held |
| Lead time and freight | Stated in the written quotation for your site | Confirmed in the quotation |
| Commercial quote | A quotation reference is issued for this page and configuration | Instant, same page |
| Subscription, from year 4 | The first 3 years are inside the quoted price | Not charged today |
One email address and your configuration, and the quotation for this Miquimon build is issued against this page. No account, no sales call required.
Direct answers to the questions buyers, installers and AI search tools ask about Miquimon.
The choice follows the vessel rather than a preference. Non-contact ultrasonic suits a tank where a probe must not enter the liquid and reads through the wall over a 20 mm to 2,000 mm range. Hydrostatic pressure suits wells and boreholes where depth matters. Capacitive suits a plastic or glass container with no contact. Optical suits a single high or low alarm point.
The non-contact ultrasonic sensor is specified at plus or minus five millimetres plus 0.5 per cent of the reading across its 20 mm to 2,000 mm range. That is a level accuracy, not a volume accuracy: converting level to litres depends on the vessel's shape, and a horizontal cylinder or a cone-bottom tank needs its own strapping table before a volume figure means anything.
The design target is five to ten years, and the real figure depends on reporting interval, radio path and temperature. A node reporting every minute over a weak LoRaWAN link will not reach ten years, and a node in a cold store will lose capacity faster. Battery state is reported with the level reading so a replacement can be planned rather than discovered.
It can drive a transfer or batching step where the site has defined the control action and its fallback. That fallback matters: a control command that depends on a radio link needs a local rule for what happens when the link drops, otherwise a full tank and a silent link combine into an overflow. Control outputs are quoted with the vessel they serve.
The gap is recorded and reported as missing data for that vessel rather than as a stable level. Missing readings are the failure mode that matters most in level monitoring, because a stale value and a steady value look identical on a dashboard. The record keeps the last time each vessel was heard so the gap is visible.
Vessels with heavy foam, dense vapour or build-up on the transducer face degrade ultrasonic sensing, and a metal wall blocks capacitive sensing from outside. A pressurised vessel needs a hydrostatic sensor rated for that pressure rather than a standard submersible. Where a site has one of these vessels, the honest answer is a different sensor, and the quotation says so.
It is quoted per vessel, because the sensing technology, the range, the process connection and whether the vessel needs a control output all change the instrument. The quotation states the sensor, the node, the first 3 years of the subscription and any installation support separately. Nothing is charged on this page; Buy now only records the price against a written quotation.
No. Miquimon measures level and raises the alarm the site configured, and it is not a certified overfill protection system. A guarantee of no overflow needs an independent high-level trip, a bund, and a procedure that acts on the alarm. The product makes the level visible and the alarm timely; the protection philosophy remains the site's responsibility.
Miquimon is quoted per site for the hardware and the scope described here. The first 3 years of service are included in the up-front project price; from year 4 the subscription is A$10 per site / month. The quotation is issued against the site assessment and states the delivery, invoicing and payment terms before anything is committed.
Miquimon ships as a kit: Miquimon ships as a level sensor and node per vessel with the mounting the vessel needs, plus the record store and alarm path; control outputs are quoted with the vessel they serve. No S5-designed radio enclosure is required, because the site gateway is a finished product bought off the shelf. Installation is a guided self-install, and the site needs mains power or the supplied battery option at the gateway location.
Miquimon is quoted against a written commercial quotation. The quotation states the configuration, the price, the lead time and the freight for your site, and sets out the ordering, invoicing and delivery terms before anything is committed.
Use the “Get instant commercial quote” form on this page, which needs only your email address and your configuration choice. The store records the request against the level-control subdomain and issues a quotation reference, so the enquiry is traceable rather than lost in a mailbox. You receive the quotation for the configuration and price shown; nothing is ordered and nothing is charged until you accept it, and the Request a quotation button is what records your interest.
A Miquimon failure is recorded as evidence and handed to the operator, not silently retried. The record keeps the measured values, the time of the event and the limit that was crossed, and the response is a documented action by your team, not an automatic decision by the device. A missing reading is treated as a missing data point, not as a pass.
Service desk, S5 System Pty Ltd. A person reads every message; the first reply comes within one business day.
WAWhatsAppMessage or call +61 468 728 893 TGTelegramJoin the S5 support group ☎Phone+61 468 728 893Talk to an S5 engineer about whether Miquimon fits your site. Pick a time that suits you. The call is free and there is no obligation.
Questions on fit, price, delivery or commissioning? A person reads every message; the first reply comes within one business day.